Knowledge Base

User Defined Model Documentation

Sample Files and Code For the Basic User: Sample DLLs and Test Case for Exciter, Governor, Machine, and Stabilizer For the Advanced Developer: GitHub Repository [recommended to Fork and continue your custom development] Has 64 bit build configured for C++ projects in Visual Studio 2019 Sample code projects for Exciter, Governor, Machine, Stabilizer, and Load […]

Tags: ,,,

March 13, 2025

PowerWorld Simulator Integration with EPRI GICHarm

Beginning with version 24, PowerWorld Simulator’s GIC add-on is integrated with the Electric Power Research Institute’s (EPRI) GICHarm tool. The latter performs harmonic analysis on grid connected devices such as capacitor banks to determine if expected geomagnetic induced currents (GICs) could cause them to trip. This integration enables an iterative analysis, summarized by: Using an […]

Tags: ,,

January 27, 2025

Extension of Full Topology Models in PowerWorld Simulator Version 24

This is the abstract and a link to the presentation associated with the PowerWorld Corporation webinar of Wednesday September 18, 2024. Link to Presentation: Extension of Full Topology Modeling in Simulator Version 24 Title: Extension of Full Topology Modeling in Simulator Version 24 Abstract: PowerWorld Simulator introduced Integrated Topology Processing (ITP add-on) in 2008 to […]

Tags: ,,,

September 9, 2024

Generic Excitation Limiter Implementation

Type C excitation system transient stability models, as per IEEE standard 421.5-2016, have the ability to allow limiters to be added at one of multiple points within the model. The excitation limiters models also allow their own parameters to be modified, in order for them to be compatible with the exciter model that is in […]

Tags: ,,

May 12, 2024

Time-Step Weather Example

This example shows how historic and forecast ERA5 weather files can be loaded into PowerWorld Simulator and be used to determine the Max MW capability of wind and solar generation. Features such as contouring and geographic data views (GDV) are also applied to enhance visualization and interpretation. The files may be downloaded here. Here is […]

Tags: ,,

February 20, 2024

Simple Weather Example

This example introduces the basic functionality of PowerWorld Simulator’s weather integration capability and how other features, such as contouring and geographic data views (GDV), can enhance visualization and interpretation of how the weather can impact wind and solar generation. The files may be downloaded here. To apply the weather data and visualize results: Open the […]

Tags: ,,

February 12, 2024

Power Transfer Limit Exceeded by OPF

The Optimal Power Flow (OPF) solution involves iteration between a linear program (LP) to adjust controls (usually generation) and a non-linear power flow. If an AC OPF is performed over a very large Area (or Super Area), the LP may attempt to dispatch generators in a manner that exceeds voltage stability margins (PV) or maximum […]

Tags: ,,

October 17, 2023

EMP Waveforms Based on Published Research

The newest builds of PowerWorld Simulator with the GIC add-on no longer contain a function to calculate time-varying series voltage inputs for EMP E3A and E3B time and spatial functions based on Oak Ridge National Laboratory (ORNL) research [1] and International Electrotechnical Commission (IEC) standards. Going forward, non-uniform time and spatially varying electric fields will […]

Tags: ,,,

October 5, 2023

Historic North American GMD Events

PowerWorld Simulator supports binary and text file formats for time and spatially-varying geomagnetic disturbance (GMD) surface electric field inputs. This format allows development of detailed solar storm scenarios based on historic events or 3D earth conductivity models. Surface electric field models developed by NOAA Space Weather Prediction Center with Empirical Magnetotelluric Transfer Functions (EMTF), which […]

Tags: ,,

August 14, 2023

WECC Area Interchange Diagram

These files include one-line diagrams and support files to show area interchange in WECC cases. A description of each file is as follows: WECCAreaDIagramGE.pwd: a one-line diagram similar to those developed in the GE PSLF program. (Interface quantities are complete in the Northwest region but may need to be added elsewhere for completeness.) WECCAreaDiagramGE.aux: auto-inserts […]

Tags: ,

July 26, 2023