PowerWorld Simulator Optimal Power Flow Reference
Quick-Start Tutorial: Includes hands-on examples that will work on the free demo version of Simulator.
Tags: FAQ,How-to,Simulator,Tutorial,User Guide
June 29, 2012
FirstRate User Guide
Provides a general description of using the FirstRate Generator Cost Model with PowerWorld Simulator. To save the file to your hard drive for easier viewing, right-click on the link and select “Save Target As …” or “Save Link As …”. FirstRate User Guide
Tags: Simulator,User Guide
June 29, 2012
Auxiliary File Format
Latest Auxiliary File Format (within WebHelp) – updated The list below are PDF documents with the format described. To save these files to your hard drive for easier viewing, right-click on the link and select “Save Target As …” or “Save Link As …”. Auxiliary File Format 24 – updated Auxiliary File Format 23 – updated Auxiliary […]
Tags: FAQ,Retriever,Simulator,User Guide
June 29, 2012
Efficient ATC Using Linear Methods
The presentation summarizes the methods used in Simulator ATC for calculating ATC values. Follow this link to see the PowerPoint slides used for most of the presentation. At the end of the presentation, Simulator ATC was demonstrated. Several screen shots are shown below which show the progression of what was covered.
Tags: Presentation,Simulator
June 29, 2012
Enabling AGC control of ISO-NE in cases where it spans multiple islands
Auxiliary File: HighgateIsland.aux (Right-click on the above file and select Save Target As to save it to your computer.) In some Eastern Interconnect planning models, the ISO-NE area spans multiple islands that contain multiple areas. Some of its buses, loads, and generators are connected to the rest of the area through the Highgate AC-DC-AC link […]
June 29, 2012
PTDF and Contingency Analysis of a New Transaction
Auxiliary File: Transaction.aux PowerWorld Case: B7OPF.pwb PowerWorld Oneline: B7OPF.pwd Output Files: PTDF.aux, BeforeTransactionCTGReport.txt, AfterTransactionCTGReport.txt (Right-click on the above files and select Save Target As to save them to your computer.) This script implements a large transaction from the left area to the top area of a seven-bus system and illustrates the effects of the transaction […]
Tags: Cases,How-to,Script,Simulator
June 29, 2012
Profit Data and Market Power Scenarios
Auxiliary File: MarketPower.aux PowerWorld Case: B7OPF.pwb PowerWorld Oneline: B7OPF.pwd Output Files: ProfitData.aux (Right-click on the above files and select Save Target As to save them to your computer.) This script records generator profit data while increasing the bid of one generator and taking a nearby generator out of service. The auxiliary file contains five script […]
Tags: Cases,How-to,Script,Simulator
June 29, 2012
Moving and Combining Generators and Comparing Power Flows
Auxiliary File: Move-Combine.aux PowerWorld Case: B7OPF.pwb PowerWorld Oneline: B7OPF.pwd Output Files: none (Right-click on the above files and select Save Target As to save them to your computer.) In this example we will use a script to combine and move generators in a seven-bus case. We will solve the power flow, move and combine some […]
Tags: Cases,How-to,Script,Simulator
June 29, 2012
Adding Multiple Generators and Performing Contingency Analysis
Auxiliary File: NewGeneratorsCTG.aux PowerWorld Case: B7OPF.pwb PowerWorld Oneline: B7OPF.pwd Output Files: NewGeneratorContingencyReport.txt (Right-click on the above files and select Save Target As to save them to your computer.) In this example we add two generators to the case and then solve the power flow, run contingency analysis and produce a contingency analysis report. There are […]
Tags: Cases,How-to,Script,Simulator
June 29, 2012
Use Spreadsheets to Create or Modify Model Objects
PowerWorld Simulator’s abilities can be extended to include all the power of a spreadsheet application such as Microsoft Excel or Corel Quattro Pro. A simple example is presented here to get you started on this powerful feature. Consider the simple seven-bus system (B7FLAT.pwb) provided with the software. B7FLAT Sample Case One-Line Diagram We are going […]
Tags: How-to,Simulator,Tip,Tutorial