Substation Information (Run Mode)

Concept Link IconSee Also

 

This dialog is used in the Run Mode to view and modify information associated with a substation record. It displays different information from the Edit Mode version of the substation dialog. To display it from Run Mode, first select Aggregation > Substations in the Model Explorer to bring up the Substation Records Display. Right-click on the substation of interest and choose Show Dialog. The Run Mode Substation Dialog has the following fields:

Substation Number

An integer identifier for the substation. You can use the spin button immediately to the right of this field to move to either the next substation (click the up arrow) or the previous substation (click the down arrow).

Substation Name and ID

Two alphanumeric identifiers for the substation.

Find By Number

To find a substation by its number, enter the number into the Substation Number field, then click this button.

Find By Name

To find a substation by its name, enter the name into the Substation Name field, then click this button.

Find By Sub ID

To find a substation by its substation ID, enter the ID into the Substation ID field, then click this button.

Find…

If the exact substation number, name and ID are not known, you can use the Find Dialog to search for and select a substation from a list of substations.

Labels

Clicking this button will open a dialog displaying the list of defined labels for the substation. New labels can also be added for the substation from the dialog as well.

View All Flows at Substation

Clicking this button will open a quick power flow display listing the buses contained in the substation.

 

Information

Load and Generation

Real and reactive load, generation, shunts, losses, and interchange for the substation.

Bus Voltages

Summary information on all buses in the substation, including total number of buses, number of dead (disconnected) buses, and minimum and maximum bus voltage and angle within the substation.

Available Gen MW/Mvar Ranges

Total amount of generation increase or decrease available for all generators in the substation.

 

Buses

The Buses table identifies the buses in the substation, and provides summary information on each.

 

Gens

The Gens table identifies the generators in the substation, and provides summary information on each.

 

Loads

The Loads table identifies the loads in the substation, and provides summary information on each.

 

Switched Shunts

The Switched Shunts table identifies the switched shunts in the substation, and provides summary information on each.

 

Tie Lines

The Tie Line Table identifies the flows on all of the substation's ties to other substation.

 

Custom

This page of the dialog can be used to enter notes about the substation. Any information entered in the memo box will be stored with the case when the case is saved to a PWB file. Custom fields can also be entered for storage with the substation object viewed.

Geography

Displays geographic information about the location of the substation, in Latitude and Longitude. Also it provides a conversion tool between Lat/Lon and UTM Coordinates.